When you compare network switches, port count and speed are easy to find. One detail that takes a little more digging is the switch ASIC, the chip that forwards packets. It helps determine how many routes the switch can handle, how much traffic it can buffer when a port gets busy, and which features are available on that hardware.
A switch can have enough 400G ports and still run out of room for your routes, ACLs or VXLAN tunnels. Those entries can share table memory, so the maximum route count and maximum ACL count may not be available together. For an EVPN leaf, the useful limit is how many entries the switch can hold with your features enabled.
Forwarding Tables Must Fit the Whole Configuration
Trident 4 can divide table memory between different kinds of forwarding entries. Giving one entry type more memory can leave less for another. Your EVPN routes, hosts, ACLs and tunnels need to fit at the same time in the memory allocation the NOS uses.
NVIDIA's SN4700 uses Spectrum-3, which supports up to 512,000 forwarding entries dynamically shared across MAC, ARP, routes, ACLs, ECMP and tunnels. That shared capacity has to hold the mix of entries your network needs. A maximum route count measured without ACLs or tunnels would leave that question unanswered.
Port Bandwidth Is Only One Limit
The ASIC sets packet-processing limits and supported port speeds, while the switch board determines which interfaces reach the front panel. A switch can use a lower-bandwidth chip variant or expose fewer ports than the chip supports. Packet memory connected to the switching die can expand the buffer, and a separate lookup processor can expand the forwarding tables.
A switch with 32 ports at 400 Gb/s has 12.8 Tb/s of switching bandwidth, counting each port once at its nominal Ethernet rate. Some switch specifications add transmit and receive rates, so compare figures on the same basis. The bandwidth columns give published chip maxima, and the port counts are chip configurations. The selected chip variant and switch board determine the front-panel ports.
Trident for Campus and Enterprise Networks
Trident belongs to Broadcom's StrataXGS family. Trident 4 targets enterprise data center and campus networks and has a programmable forwarding pipeline.
| Chip | Bandwidth |
|---|---|
| Trident 3-X3 | 560 Gb/s |
| Trident 3-X7 | 3.2 Tb/s |
| Trident 4 | 12.8 Tb/s |
| Trident 5-X12 | 16.0 Tb/s |
Trident 3-X3, the BCM56370 series, supports uplinks up to 100GbE, stacking and VXLAN. BCM56370 and BCM56375 have multigigabit downlinks for access points, while other parts in the series have GbE downlinks. BCM56375 has BroadScan flow analytics for monitoring traffic flows. Broadcom's overview and ordering table disagree on BroadScan support for BCM56370, so confirm that feature for the exact part before ordering.
Trident 3-X7, BCM56870, supports up to 32 ports at 100GbE. It has a programmable pipeline for overlays, shared packet buffering and in-band telemetry for monitoring traffic. Micas Networks' M2-W6510-32C uses BCM56870.
Trident 4, BCM56880, supports up to 32 ports at 400GbE. Edgecore's DCS240, also named AS9726-32DB, uses this chip. Alpha Networks' SNJ-61x0-320F also uses Trident 4. Trident 4 can mark ECN based on latency and export streaming telemetry for traffic monitoring.
HPE Juniper's QFX5130E-32CD uses Trident 4-X11E. Use the QFX5130E-32CD's port layout, bandwidth and NOS limits when checking whether it fits your network.
Trident 5-X12 supports 48 downlinks at 200GbE and eight uplinks at 800GbE. Its NetGNT neural-network engine works alongside the programmable pipeline. NetGNT can recognize traffic patterns spanning ports and buffers, such as many flows converging on one output, and trigger congestion control.
A campus switch can have unused PoE budget and still be unable to power an access point. PoE support and the power allocated to each port have to meet the connected device's requirements as well as fit within the switch's total budget.
Port Density in a Tomahawk Fabric
Tomahawk is another StrataXGS family, used in data center and AI fabrics. More ports at a given speed, or higher radix, let each switch connect more servers or neighboring switches at each tier.
| Chip | Bandwidth | Ports, up to |
|---|---|---|
| Tomahawk 3 | 12.8 Tb/s | 32 × 400G |
| Tomahawk 4 | 25.6 Tb/s | 64 × 400G |
| Tomahawk 5 | 51.2 Tb/s | 64 × 800G |
| Tomahawk 6 | 102.4 Tb/s | 64 × 1.6T |
| Tomahawk Ultra | 51.2 Tb/s | 64 × 800G |
Port speed also depends on how electrical lanes are grouped. A serializer/deserializer, or SerDes, sends and receives signals on each lane. Several lanes can form one Ethernet port, so a 100G lane does not mean a 100GbE port.
Tomahawk 3, BCM56980, uses 56G PAM4 SerDes for 50G-class Ethernet lanes. The 56G figure is the SerDes rating, while 50G is the nominal Ethernet lane class. Tomahawk 3 has a shared packet buffer and BroadView Gen3 telemetry, and its dynamic load balancing distributes traffic across links. The Tomahawk 4 BCM56990 family includes chip variants with 50G or 100G PAM4 SerDes, with shared buffering, congestion management and in-band telemetry.
Tomahawk 5, BCM78900, uses 100G PAM4 lanes, with eight lanes forming an 800GbE port. Adaptive routing and dynamic load balancing distribute traffic across paths, with end-to-end congestion control for AI/ML workloads. Tomahawk 5 can serve leaf, aggregation, edge and spine roles in data centers and AI/ML clusters. Celestica's DS5000 uses Tomahawk 5.
The Tomahawk 6 BCM78910 series has 100G and 200G PAM4 variants for AI scale-up and scale-out networks. The BCM78914 variant uses 200G PAM4 lanes. Eight lanes form each port in its 64-port 1.6TbE configuration. Adaptive routing distributes traffic across paths, and the chip also supports end-to-end congestion control.
Tomahawk Ultra, BCM78920, targets HPC and AI scale-up. It uses 100G PAM4 SerDes and supports hardware Link Layer Retry, credit-based flow control and in-network collectives. Link Layer Retry recovers link errors in hardware. For retry and credit-based flow control, both link partners need to support the same mechanisms. Check the switch port and the Ethernet interface at the other end of each link.
Deep Buffers and Large Routing Tables
Jericho and Qumran belong to Broadcom's StrataDNX family. In modular or disaggregated systems, Jericho chips can connect to separate fabric chips that carry traffic between switching devices. Qumran chips suit switch-router designs that forward traffic without a separate fabric chip.
Jericho2c+, BCM88850, has deep packet buffers and hierarchical traffic management for scheduling traffic by service or customer. A separate lookup processor can expand its forwarding tables. Jericho2c+ serves carrier core and edge routers as well as data center leaf, spine and interconnect switches.
High-bandwidth memory, or HBM, uses memory dies separate from the main switching die. Both Jericho2 BCM88690 and Jericho2c+ combine on-chip packet buffers with HBM inside the same package. Compare the installed on-chip packet memory and HBM separately when choosing a switch.
Qumran3D, BCM88870, supports HBM packet memory and hierarchical traffic management. It serves carrier Ethernet, edge and core routing, peering, data center and cloud networks. UfiSpace's S9600-32X uses Qumran2c, BCM88820.
Jericho3-AI, BCM88890, works with BCM88920 fabric elements. The system uses load balancing and end-to-end scheduling to prevent head-of-line blocking for AI/ML workloads. Test the Jericho3-AI switches and fabric elements as one system with the traffic your cluster will carry.
Spectrum and RoCE Depend on the Software
Spectrum chips combine programmable forwarding and hardware telemetry with on-chip packet memory shared across ports. A queue can stop accepting packets at its configured limit while shared memory is still available. The total packet memory is therefore not a measure of how much one queue can absorb.
| Chip | Bandwidth | Ports, up to |
|---|---|---|
| Spectrum-2 | 6.4 Tb/s | 16 × 400G |
| Spectrum-3 | 12.8 Tb/s | 32 × 400G |
| Spectrum-4 | 51.2 Tb/s | 64 × 800G |
| Spectrum-6 | 102.4 Tb/s | 128 × 800G |
Spectrum-2 and Spectrum-3 use 50G PAM4 SerDes. Spectrum-2 has 42 MB of shared packet memory, and Spectrum-3 has 64 MB. Both support single-pass VXLAN routing, ECN, PFC and What Just Happened telemetry.
Spectrum-3 has adaptive-routing hardware, but Cumulus Linux 5.9 supports adaptive routing on Spectrum-4 only. In Cumulus Linux 5.9, adaptive routing works with RoCEv2 unicast and VXLAN-encapsulated RoCE traffic on 200G or 400G Layer 3 interfaces. The next-hop router interfaces must be in the default VRF. Adaptive routing in this release is unavailable on 800G links, Layer 3 subinterfaces, SVIs, bonds and bond members. The 800G port capability alone therefore does not make adaptive routing available at that speed in Cumulus Linux 5.9.
At 51.2 Tb/s, Spectrum-4 uses 100G PAM4 SerDes, while the 102.4 Tb/s Spectrum-6 uses 200G PAM4 SerDes. Both combine shared on-chip buffering with RoCE features for adaptive routing, congestion control and performance isolation. Lower-bandwidth Spectrum-4 variants can use different lane rates.
NVIDIA's SN5600 uses Spectrum-4. Spectrum switches serve leaf, spine and storage networks, including RoCE storage using NVMe-oF.
Spectrum-X combines switches, compatible NICs and software. In the Spectrum-4 and BlueField-3 SuperNIC implementation, packets from one flow can take different paths to spread traffic across the fabric. The receiving BlueField-3 SuperNIC places out-of-order data in the correct memory locations.
BlueField-3 SuperNIC and ConnectX-8 SuperNIC are examples of Spectrum-X network adapters. With Spectrum-4, SuperNICs use switch telemetry to adjust transmission rates.
For Kubernetes deployments using Network Operator 26.7.0, the Spectrum-X profile contains NIC settings for the NVIDIA reference design you chose. If NIC firmware needs updating, use firmware for the exact ConnectX or BlueField device. Test adaptive routing and congestion control with the switches, NICs, software, firmware and topology you will deploy.
How Much Buffer One Queue Can Use
A packet buffer holds traffic that arrives faster than an output can transmit it. Several senders converging on one receiver, or a fast interface feeding a slower link, can fill a queue even when the rest of the switch is lightly loaded.
For 100 microseconds, suppose four senders each deliver 100 Gb/s of packet data to one output that transmits packet data at 100 Gb/s. The queue grows at 300 Gb/s and gains 3.75 MB of packet data during the burst. That is 3,750,000 bytes of packet data before packet storage overhead.
In SONiC, buffer pools, reserved memory and per-queue or priority-group profiles set separate limits. Check which profile is bound to the queue or priority group, the threshold that limits accepted packets and the shared pool it can use. A queue with a limit below the burst size can drop packets while memory elsewhere on the chip remains free. Other queues and packet storage overhead also consume memory.
A larger buffer can absorb a longer burst, but it cannot make an overloaded output transmit faster. Persistent queues add delay, so buffer sizing and queue management belong in the same design. When a burst exceeds the usable on-chip buffer, check that the deep-buffer switch can give the affected queue enough memory to hold it. The application also needs to tolerate the resulting queueing delay. For storage traffic that fits within the on-chip buffer and delay limits, HBM is not a requirement.
The NOS Controls Which Features Run
With a white box switch, the hardware and a compatible NOS can be selected separately. Open networking requires software support for the exact switch platform and hardware SKU. Find the switch on the SONiC supported platforms page, then confirm support in the distribution and release you will run.
In SONiC, the Switch Abstraction Interface, or SAI, provides a common interface for programming the ASIC. The vendor's SAI implementation and SDK drive the chip. The NOS, SAI implementation and SDK must implement a hardware function before you can use it. The same ASIC can therefore offer different features or forwarding-table limits across releases.
MCLAG in SONiC depends on software that synchronizes state between peer switches and programs their ASICs. In the SONiC MCLAG design, port isolation uses hardware isolation groups where the platform supports them, with an ACL fallback. On the NOS release you will run, test traffic to and from devices attached to the MCLAG pair, including paths over the peer link. Include unicast, broadcast, unknown-unicast and multicast traffic, and check for duplicate delivery to devices connected to both switches. Repeat the forwarding checks when a link or peer fails and when service is restored.
Optics, Power and Cooling Must Fit the Switch
Optics and cables also depend on the switch and NOS release. Order the exact optics, cables and breakout combinations supported at both ends of each link by the hardware and NOS releases you tested. Match electrical lane mapping and FEC at both link ends, and keep each module within its port's power limit.
Check maximum system draw with those optics and the PSU capacity available under the required redundancy arrangement. The facility's input power must meet the switch's requirements. Match cooling and airflow direction to the rack.
Before You Order
Record the exact ASIC part and silicon revision, switch SKU and board revision, then the NOS distribution, edition and release. Include any licenses the required features need. You can reach out to our engineers.
For campus access, check the physical access interfaces and uplinks, and confirm that the switch and NOS support the switch-stacking arrangement you need. Match each connected device's PoE type and class to the port and its power allocation, then check the total PoE budget for all connected devices.
For an EVPN leaf, load your route, host, ACL and tunnel entries together with the NOS memory allocation you will use. Measure forwarding performance at the required packet rates and expected frame sizes, with telemetry and MCLAG enabled where your network uses them. Compare transmitted and received frame counts to measure loss.
For RoCE in storage or AI networks, use the switches, NICs, firmware and topology you will deploy. Confirm adaptive routing and load balancing for the NOS release, link speeds, traffic types, interfaces and VRFs your network uses. Test congestion control, ECN and the PFC behavior your design requires.
Check the installed on-chip packet memory and HBM separately, then the shared-pool, reserved-memory and per-queue limits. Test the expected burst duration and traffic pattern, including fast ports feeding slower outputs, and measure whether queueing delay stays within the application's limit.
For an installation with a fixed date, allow for switch lead times and confirm delivery dates for switches, optics and cables together. Leave time to test the complete configuration before it is needed. Choose a switch that holds your forwarding entries together and passes the performance, buffer and interoperability checks, then order the hardware and software revisions used in those tests.
Hardware Nation is a partner of Accton/Edgecore, Alpha Networks, Celestica, HPE Juniper, Micas Networks, NVIDIA and UfiSpace.
Alex Cronin
Alex Cronin is the founder of Hardware Nation and Nanites AI. He is a graduate of Georgia Tech with 20 years of experience in networking and data center infrastructure across enterprises, service providers and hyperscalers. His work spans traditional and open networking, production SONiC deployments, multivendor integration and direct collaboration with manufacturers and engineering teams. Hardware Nation has served organizations including NASA, Lockheed Martin, Accenture, Stanford University and Georgia Tech.
Alex leads engineering teams and contributes directly to architecture, code, integration and evaluation. At Nanites AI, he has led nearly two years of development of an agentic NetOps platform for network troubleshooting. He also develops AI automation for product research and leads business operations at Hardware Nation.
Nanites AI has been cited in Gartner’s Market Guide for Agentic NetOps Software, covered by InformationWeek and discussed by Cisco DevNet. It was selected as one of 12 finalists from more than 400 applicants in the 2025 T Challenge, organized by T-Mobile and Deutsche Telekom. Alex has presented his work at Deutsche Telekom in Bonn, CableLabs and Network X Americas.